select.parts
Availability check

Seeed Studio box PCs rated to -30 °C or colder for northern Canada

Asked as: “Does Seeed Studio have a box PC rated down to -30°C or colder? Outdoor install in northern Canada.”

Answered by the Rapidflare agent

No — I could not find a Seeed Studio box PC rated to −30 °C or colder. Across all 16 Seeed Studio box PCs in our catalog, the coldest rated operating temperature is −20 °C.

Seeed Studio's lineup, by minimum operating temperature

Product lineMin. operating tempNotes
reComputer Industrial J4012/J4011/J3011/J3010/J2012/J2011−20 °CFanless, IP40; the −20 to 60 °C range holds only with airflow seeedstudi... +1seeedstudio.com ↗“thermal.min_operating_temp_c=-20 °C”seeedstudio.com ↗“Requires airflow”
reComputer Rugged J4012 (IP66)−20 °COutdoor-rated IP66 enclosure, but still −20 °C at the low end seeedstudi...seeedstudio.com ↗“thermal.min_operating_temp_c=-20 °C, identity.manufacturer=Seeed Studio, identity.product_line=reComputer Rugged”
reComputer J3010/J3011/J4012/J4011/J2022/J2021−10 °CStandard enclosed desktop units seeedstudi...seeedstudio.com ↗“thermal.min_operating_temp_c=-10 °C”
reComputer J1010 / J1020 v2 (Jetson Nano)0 °CEOL seeedstudi...seeedstudio.com ↗“thermal.min_operating_temp_c=0 °C”

Even Seeed's IP66 Rugged line, which is the most outdoor-suited of the group, tops out at −20 °C minimum — 10 °C short of your requirement for a northern Canada install. The reComputer Rugged J3011 has no minimum operating temperature listed in the catalog, so I can't confirm it either way. One thing to be aware of: the Seeed Industrial units' −20 to 60 °C range also carries a "requires airflow" condition, which is a further constraint for a sealed outdoor enclosure. seeedstudi...seeedstudio.com ↗“Requires airflow”

Alternatives from other partners rated −30 °C or colder

If you can look beyond Seeed Studio, several partner box PCs in the same catalog meet −30 °C or −40 °C, several with outdoor-grade IP ratings:

ProductMin. op. tempIP ratingModule
NEXCOM ATC 3540-IP7-4C−30 °CIP67Jetson Orin NX (100 TOPS) ai.nexcom...ai.nexcom.com ↗“thermal.min_operating_temp_c=-30 °C”
NEXCOM ATC 3560-IP7-NXAI4CR−35 °CIP67Jetson Orin NX (100 TOPS), EN 50155 OT3 nexcom.comnexcom.com ↗“thermal.min_operating_temp_c=-35 °C”
Neousys NRU-230V-AWP−40 °CIP66Jetson AGX Orin (275 TOPS) neousys-te...neousys-tech.com ↗“thermal.min_operating_temp_c=-40 °C”
AVerMedia D135OXB−40 °CIP65Jetson Orin NX (100 TOPS), 8x GMSL cameras avermedia...avermedia.com ↗“thermal.min_operating_temp_c=-40 °C”
Lanner EAI-I131−40 °Cnot listedJetson Orin NX/Nano (100 TOPS) lannerinc...lannerinc.com ↗“thermal.min_operating_temp_c=-40 °C”
Advantech MIC-733-TS−34 °Cnot listedJetson AGX Orin 32GB (200 TOPS), NEMA TS2 advantech...advantech.com ↗“thermal.min_operating_temp_c=-34 °C”

For an exposed outdoor site where −30 °C or colder is expected, the NEXCOM ATC IP67 series and the Neousys NRU-230V-AWP (IP66, −40 °C) are the strongest fits in that list. Note that several of these temperature ranges carry conditions (e.g. "Depends on power mode", "Depends on PoE load"), so confirm your specific power mode and PoE load against the vendor datasheet before committing. ai.nexcom...ai.nexcom.com ↗“Depends on power mode, Depends on PoE load”

To summarize plainly: I found no Seeed Studio box PC at −30 °C or colder; their best is −20 °C. The matches above are from other vendors, not Seeed Studio.

Sources

  1. reComputer Industrial J4012 seeedstudio.com
  2. reComputer Industrial J4011 seeedstudio.com
  3. reComputer Rugged J4012 seeedstudio.com
  4. seeedstudio.com seeedstudio.com
  5. reComputer J1010 seeedstudio.com
  6. ATC 3540-IP7-4C ai.nexcom.com
  7. ATC 3560-IP7-NXAI4CR nexcom.com
  8. NRU-230V-AWP neousys-tech.com
  9. D135OXB avermedia.com
  10. EAI-I131 lannerinc.com
  11. MIC-733-TS advantech.com
  12. reComputer J3010 seeedstudio.com